Place of Origin |
Japan |
Brand Name |
omron |
Model Number |
G2R-2-S DC24(S) BY OMB |
Theory |
Voltage Relay |
Usage |
General Purpose |
omron G2R-2-S DC24(S) BY OMBRelay specifications datasheet Product classificationMonostable relaysCoil ratings24 VDC 21.8 mACoil resistance1100 OhmOperate voltage (Set voltage)70% Max.Release voltage (Reset voltage)15% Min.Power consumption (Single stable)Approx. 0.53 WIndicatorNot equippedCoil surge killerNot equippedContact TypeDPDTContact methodSingleContact materialContact body material: Ag alloyContact rated load250 VAC 5 A (Resistive load(cos phi=1)) 250 VAC 2 A (Inductive load(cos phi=0.4)) 30 VDC 5 A (Resistive load) 30 VDC 3 A (Inductive load(L/R=7ms))Maximum switching voltage380 VAC (Resistive load(cos phi=1)) 380 VAC (Inductive load(cos phi=0.4)) 125 VDC (Resistive load) 125 VDC (Inductive load(L/R=7ms))Maximum switching currentAC: 5 A (Resistive load(cos phi=1)) AC: 5 A (Inductive load(cos phi=0.4)) DC: 5 A (Resistive load) DC: 5 A (Inductive load(L/R=7ms))Maximum switching powerAC: 1250 VA (Resistive load(cos phi=1)) AC: 500 VA (Inductive load(cos phi=0.4)) DC: 150 W (Resistive load) DC: 90 W (Inductive load(L/R=7ms))Failure rate10mA at 5VDC (failure level: P Reference value)Ambient humidityOperating: 5 to 85% RH CharacteristicsContact resistanceMax 50mOhm Measuring the voltage drop across the contacts by applying test voltage/current as 5VDC 1AOperating time (set time)15 ms Max.Insulation resistanceBetween coil and contacts: 1000 M Ohm Min. (at 500 VDC) Between contacts of different polarity: 1000 M Ohm Min. (at 500 VDC) Between contacts of same polarity: 1000 M Ohm Min. (at 500 VDC)Dielectric strengthBetween coil and contacts: 5000 VAC 50/60 Hz for 1 min (Leakage current 3mA 50/60Hz 1min) Between contacts of different polarity: 3000 VAC 50/60 Hz for 1 min (Leakage current 3mA 50/60Hz 1min) Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 3mA 50/60Hz 1min)Vibration resistance (Destruction)10 to 55 to 10 Hz 0.75-mm single amplitude (1.5-mm double amplitude) (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)Vibration resistance (Malfunction)10 to 55 to 10 Hz 0.75-mm single amplitude (1.5-mm double amplitude)Shock resistance (Destruction)1000 m/s2 (No defect in appearance and construction after applying shock in each directions 3 times.)Shock resistance (Malfunction)200 m/s2Endurance (Mechanical)10000000 operations Min.Endurance (Electrical)100000 operations Min.Applicable standard (UL)File number: E41643Applicable standard (CSA)File number: LR31928Applicable standard (VDE)6166Applicable standard(Other)Electrical Appliance and Material Safety Law